Unlike steel-reinforced cables, all-dielectric designs use zero metal. This eliminates lightning attraction and corrosion. Fun fact: These cables weigh 40% less yet survive 150mph winds. The secret? Kevlar strength members and UV-resistant polyethylene jackets.
Factor | All-Dielectric Cable | Steel-Reinforced Cable |
---|---|---|
Lightning Risk | Near-zero | High (grounding needed) |
Weight | 0.25 lbs/ft | 0.42 lbs/ft |
Lifespan | 25 years | 15-20 years |
Installation Cost | $0.85/ft | $1.10/ft |
Ice Resistance | High (non-conductive) | Moderate |
Source: OSP Magazine Field Study 2024
Route Survey: Identify tree clearance (min 15 ft vertical)
Pole Selection: Use Class 1 poles for >200 ft spanswww.adsscable.cn
Hardware Setup: Install ADSS brackets (avoid metallic clamps!)
Tension Control: Maintain 600-800 lbs with dynamometers
Sag Adjustment: Allow 18-24" sag per 100 ft in summer
⚠️ Critical Warning: Over-tensioning causes 71% of mid-span breaks!
During 2024’s record storm season, all dielectric aerial outdoor Io me e ‵ tau o ‵ lois withstood 2" ice buildup and EF2 tornado winds. Our dielectric cables had zero failures vs. 37% failure rate in steel-reinforced lines. Key savior? The helical design disperses stress.
Steel seems cheaper upfront. But here’s the twist: All-dielectric cables slash 3 costs:www.adsscable.cn
No grounding kits ($120/splice saved)
No corrosion repairs ($2K/mile/year)
No lightning damage ($18K/outage avoided)
These cables don’t rely on thickness. Instead, central loose tube fiber cores float in thixotropic gel, surrounded by aramid yarn. This absorbs vibration—like how skyscrapers sway in quakes.
Confirm dielectric strength member (no metal)
Verify UV rating >20 years (check sheath markings)
Install vibration dampers every 150 ft
www.adsscable.cn
Use torque wrenches on tension hardware
Schedule bi-annual drone inspections
Q: Can rodents chew through these cables?
A: Yes—but rodent-resistant jackets (cost 15%) reduce risk by 90%.
Q: What’s the maximum span length?
A: 300 ft with standard ADSS; 500 ft with reinforced dead-ends.
Q: How does temperature affect sag?
A: For every 30°F change, sag varies 1.2%—always recalibrate seasonally.
Q: Are dielectric cables compatible with existing hardware?
A: Mostly—but replace metal suspension clamps with dielectric versions.
Q: Why choose gel-filled over dry cores?
A: Gel blocks water ingress (critical in humidity)—dry cores need pressurized closures.